Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $2000.00/ Piece |
Local Area: | Unknown |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Function: | Insulation Resistance Test, Voltage Test |
---|---|
Rated Voltage(V): | 250, 500, 1000, 2500, 5000V, 10kv |
Test Voltage(V): | Rated Voltage*(1+-10%) |
Test FunctionOutput VoltageMeasure RangeAccuracyResolutionInsulation Resistance250V(±10%)0~10MΩ±3%rdg±5dgt0.01MΩ10~100MΩ0.1MΩ100~1000MΩ1MΩ1G~10GΩ±5%rdg±5dgt0.01GΩ500V(±10%)0~10MΩ±3%rdg±5dgt0.01MΩ10~100MΩ0.1MΩ100~1000MΩ1MΩ1G~10GΩ±5%rdg±5dgt0.01GΩ1000V(±10%)0~20MΩ±3%rdg±5dgt0.01MΩ20~200MΩ0.1MΩ200~2000MΩ1MΩ2G~20GΩ±5%rdg±5dgt0.01GΩ2500V(±10%)0~2000MΩ±3%rdg±5dgt1MΩ2000MΩ~20GΩ±5%rdg±5dgt0.01GΩ20GΩ~200GΩ±20%rdg±10dgt0.1GΩ5000V(±10%)0~2000MΩ±3%rdg±5dgt1MΩ2000MΩ~20GΩ±5%rdg±5dgt0.01GΩ20GΩ~200GΩ±20%rdg±10dgt0.1GΩ200GΩ~1000GΩ±20%rdg±10dgt1GΩ10kV(±10%)0~2000MΩ±3%rdg±5dgt1MΩ2000MΩ~20GΩ±5%rdg±5dgt0.01GΩ20GΩ~200GΩ±20%rdg±10dgt0.1GΩ200GΩ~1000GΩ±20%rdg±10dgt1GΩ
Test FunctionMeasure RangeAccuracyResolutionDC VoltageDC 0.0V~1000V±1.5%rdg±3dgt0.1VAC VoltageAC 0.0V~750V±1.5%rdg±3dgt0.1V
FunctionInsulation resistance test, voltage testbase conditions23°C±5°C,below 75%rhRated voltage(V)250, 500, 1000, 2500, 5000V, 10kVTest Voltage(V)rated voltagex(1±10%)Insulation Resistance Range(GΩ)0.01MΩ~1000GΩInsulation Resistance Insulation0.01MΩDC Voltage Range0~1000VDC Voltage resolution0.1VAC Voltage Range0~750VAC Voltage resolution0.1VOutput short-circuit Current≥3mA(5kV)Absorption Ratio and Polarization Index MeasurementHavePower Supply12V rechargeable batteryBacklightControllable gray screen backlight, suitable for use in dim placesDisplay mode4-bit large LCD display, gray screen backlightLCD display size108mmx65mmInstrument sizeL/W/H:277.2mmx227.5mmx153mmUSB interfaceWith USB interface, software monitoring, storage data can be uploaded to the computer, save the printCommunication LineUSB communication line 1PCTest LineHigh voltage robs red 3meter, high voltage test line black 1.5meter, green 1.5meterData Storage500 groups, "FULL" symbol indicates that storage is fullData ReviewData review function: "MR" symbol displayOverflow DisplayExceed measurement range overflow function: "OL" symbol displayAlarm FunctionAlarm when the measured value exceeds the alarm setting valuePower ConsumptionStandby: 30mA Max (backlight off)Turn on backlight: 42mA MaxMeasure:300mA Max (backlight off)Instrument weight2720g (including battery)Battery voltageWhen the battery voltage is low, low battery symbol " "will displayAutomatic shut-downautomatic shutdown after 15 minutes bootInsulation Resistance≥50MΩ (between Measuring line and housing)Pressure ResistanceAC3kV/50Hz 1minWorking Temperature and Humidity-10ºC~+50ºC<85%RHStorage Temperature and Humidity-15ºC~+55ºC<90%RHSuitable for Safety RegulationsIEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529(IP54) pollution grade 2, CAT III 300V