Distribution Box, Electrical Distribution Box, Pz65 Distribution Box manufacturer / supplier in China, offering High Quality Pz65 Electrical Distribution Box, Pz70 Type Outdoor Power Electrical Steel Distributionb Box, Pz65 Low Voltage Metal Switchgear Electrical Distribution Panel Box and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $715.00/ Piece |
Local Area: | Binzhou, Shandong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T |
Brand: | CHINT |
---|---|
Type: | Distribution Metering Box |
Structure: | IP56 |
Certification: | ISO9001:2000, CCC, Ce |
Structure Features
Type XL-36 low voltage control cabinet is of enclosed type and its case is made of stainless steel.The operation handle is installed at the upper part of right pole for power switching one voltage meter is installed in the front distribution case to indicate bus voltage.The front of the distribution cabinet has door which,in case of opening,keeps the parts in the cabinet exposure for convenient maintenance.
This distribution cabinet adopts domestic parts and has such features as compact structure,easy maintenance and flexible combination.The distribution cabinet,in addition to the air curcuit breaker and fuse as short circuit protection,also installs contactor and thermal relay.The operation button and indication light are installed in the front door.
Application
XL-36 motive electricity switchgear cabinet is suitable for three-phase four-wire power system with AC frequency of 50Hz and voltage of 380V. Widely used to the low voltage power distribution systems of power plants, transformer substations, petroleum, chemical, metallurgical, machinery and other industrial enterprises and high-rise building for power transformation, distribution and controlling.
Normal operating conditions
Ambient air temperature : -5°C ~ +40°C;Daily average temperature(Within 24h): ≤+35ºCRelative humidity: ≤50% at the maximum temperature of +40ºC and may be higher at lower temperature, for example, 90% at +20ºC.Altitude:≤2,000m;Installation inclination:≤ 5°;Installation places: Indoor; without fire, explosion risk, serious pollution, rain immersion, violent vibration, chemical corrosion and conductive dust.Special operation conditions
If the switchgear will be used in conditions that exceed the normal environmental conditions, users should consult with the manufacturer.
Technical Parameter
No.
Item(Unit)
Data
1
Rated Operational Voltage(V)
AC380
2
Rated Insulation Voltage(V)
AC500
3
Rated Frequency(Hz)
50
4
Main Bus Rated Current(A)
≤630
5
Main Bus Rated Short-time Withstand Current(kA)
≤15
6
Rated Impulse Withstand Voltage (kV)
6
7
Standard
GB7251.12
8
Protection Degree
IP30
Contact:May Meng